1, Internet cafes should be located on the first floor, second floor or third floor near the external walls of first-and second-class fire-resistant buildings. When it is installed on the basement level or above four floors above the ground, it must meet certain fire prevention conditions, such as: the height difference between the basement level and the outdoor entrance level should not be greater than 10m, and the building area of a hall and room should not be greater than 200m2, so smoke control facilities should be installed.
2. It shall not be located in ancient cultural relics buildings, museums and library buildings, and shall not be adjacent to important warehouses and dangerous goods warehouses; Shall not be rebuilt in residential buildings; Should not be set on the second floor or below; Should not be set at the two sides or ends of the bag-like walkway.
3. In a building, song and dance entertainment places such as Internet cafes should be separated from other places. Among them, the fire resistance of partition wall is not less than 2h, the fire resistance of floor slab is not less than 1h, and the doors opened on the wall are not less than Class B fire doors.
4. The number of safety exits should not be less than 2. When the building area is not more than 50 square meters, 1 evacuation exits can be set. In order to prevent people from crowding, the safety exits should be distributed, and the horizontal distance between the nearest edges of two adjacent exits should not be less than 5m.
5, when the building is more than 3 floors or set in the basement, evacuation stairs should be in the form of closed stairwells. Stairwells should not be used in basements, semi-basements and the ground. When the stairwell must be used, the first floor should be separated from other parts by a partition wall, and the door opened on the partition wall should be clearly marked. Fire doors of not less than Grade B shall be adopted.
6, the width of the exit, evacuation stairs, walkways to ensure timely and effective accommodation of personnel evacuation places.
7. The exit should be kept clear. There should be no threshold or steps at the exit, and the evacuation door should be opened outward. Rolling doors, revolving doors, hanging doors and sliding doors should not be used, and doors, windows, screens and other obstacles that affect evacuation should not be set at the door.
8, set up the fire accident emergency lighting, lighting power supply time shall not be less than 20min. Lighting evacuation signs should be set at the exits, evacuation passages and stairs. Indicating signs should be set at the top of doors, evacuation passages and wall corners below the ground1m. The spacing of indicating signs on the walkway should not be more than 20m. Luminous evacuation signs should be set on or near the ground of evacuation walkways and main evacuation passages.
Second, the Internet cafe fire acceptance specification
1, fire administrative licensing procedures, whether the Internet cafe has gone through the fire safety inspection procedures before construction, acceptance and opening according to law.
2, fire facilities and fire equipment, whether in accordance with the requirements of the specification set fire facilities and fire equipment. When the single floor is not more than 300m2, at least two 4kg ammonium phosphate dry powder fire extinguishers shall be equipped; For those exceeding 300m2, at least 1 4kg ammonium phosphate dry powder fire extinguisher shall be added every 150m2. Multi-layer, each layer shall not exceed 300m2, and each layer shall be equipped with at least two 4kg ammonium phosphate dry powder fire extinguishers; When the floor is more than 300m2, at least 1 4kg ammonium phosphate dry powder fire extinguisher shall be added for each floor exceeding 150m2. Whether the fire-fighting equipment is regularly overhauled and ensured to be complete and easy to use.
3, safe evacuation, the number of evacuation doors, open direction, safe evacuation instructions should meet the requirements. Whether there are barriers such as thresholds, steps, curtains and screens. Whether shutter doors, revolving doors, hanging doors and sliding doors are used at the exit. It is forbidden to block or lock windows, safety evacuation passages and safety exits during business hours. Internet cafes are not allowed to have fixed closed doors and windows fences. Evacuation signs and emergency lighting requirements for fire accidents.
4. According to the requirements, the "two capabilities" of fire safety have been built and the combat effectiveness has been generated; In a prominent position, the "Nine Small Places" fire safety construction standards were hung.
5. Open flame lighting and smoking are prohibited in Internet cafes, and hanging smoking is prohibited; Whether to use open flames in violation of regulations.
6. It is forbidden to carry and store inflammable and explosive articles.