Current location - Training Enrollment Network - Early education courses - Shandong Provincial Health and Health Commission kindergarten air quality inspection regulations?
Shandong Provincial Health and Health Commission kindergarten air quality inspection regulations?
Main building standards and building equipment

Nineteenth kindergarten buildings should adhere to the principles of safety, applicability, green, energy saving, environmental protection, economy and beauty, and create an educational environment with perfect functions, suitable for the healthy development of children's physical and mental health and entertaining. Public kindergartens are not allowed to build luxury kindergartens. Kindergarten should be a building with three floors or less and a bungalow that meets the building standards.

(a) the design and construction of kindergarten buildings must conform to the national Standard for Kindergarten Construction (JB175-2016) and the Code for the Design of Nurseries and Kindergartens (JGJ39-2016) and related codes and standards.

(2) Children's activities shall meet the following requirements:

1. should be located on the third floor and below, and it is forbidden to be located in the basement or semi-basement. Small class living room should be on the first to second floor, middle class and large class living room should be on the first to third floor.

2. Class activity units should meet the functional needs of children's activities and life. Children's activity room should have good natural lighting, natural ventilation and air convection conditions.

3. The attic or mezzanine shall not be built as a dormitory in the class activity unit. Activity rooms and dormitories can be set separately or combined.

4. Ensure that each child has a bed, and bunk beds are not allowed, and the side of the bed shall not be arranged near the external wall.

(three) building fire protection should meet the requirements of the code for fire protection design of buildings, and the fire resistance rating should not be lower than Grade II.

(four) the building structure should meet the requirements of the current national code for seismic design of buildings, and the seismic fortification category should not be lower than the key fortification category.

(five) the indoor clear height of the main buildings in the garden shall meet the following requirements:

1. The class activity unit should not be less than 3.00m. ..

2. The comprehensive activity room should not be less than 3.90m m.

(six) the entrance and exit of the kindergarten, roads, corridors and toilets. , should be designed according to the current national standard "Code for Barrier-free Design" (GB50763).

(7) The halls and corridors shall meet the following requirements:

1. The reception hall (entrance hall) of the morning check-up in kindergarten should be spacious and bright, which is conducive to the distribution of people and short stay.

2. The width of the unilateral corridor should not be less than 1.80m, and the width of the middle corridor should not be less than 2.40m

3. The balcony should have closed windows. When the kitchen and children's dining place are not in the same building, a closed connecting corridor should be set up.

4. There should be no steps for children to enter and exit in the foyer and corridor. When there is a height difference on the ground, an anti-skid ramp should be adopted, and its gradient should not be greater than 1: 12. The walls of evacuation walkways should not have pilasters, pipes, fire hydrant box, fire extinguishers, billboards and other protrusions 2m below the ground.