Current location - Training Enrollment Network - Books and materials - Library construction organization design scheme?
Library construction organization design scheme?
What is the specific content of the library construction organization design scheme? Here, Zhong Da Consulting will answer your questions.

Chapter I Project Overview

Project Name: Library Phase II Project

Construction site: No.89, XX North Road (on campus)

Designer: Municipal Education Architectural Design and Research Institute Co., Ltd.

Structure/hierarchy: frame/four floors (five floors locally)

The following is an overview of the project:

This project is connected with the library building of Institute of Technology, with a building area of 4930m2, a total height of 19.4m, a design fire resistance rating of Class II, a service life of 50 years, an important building category of Class C, a building safety rating of Class II, a building site category of Class III, a moderately weak site and a moderately liquefied site, with Tg=0.306s, a building pile foundation safety rating of Class II and a seismic fortification intensity of 7.

I. Overview of architectural design:

1 Dampproof of wall foundation: Su J9501-11,not provided where there are ring beams.

2. Ground practice: the stacks are partially overhead: terrazzo floor, Su J950 1-5/3, with copper bars.

Hall part: granite floor, Su J 9501-18/2; Fire control room: single-story hardwood floor, Su J 9501-20/2; See Su J9501-14/2 for the light gray non-slip floor tile in the bathroom; The rest: terrazzo floor, Su J950 1- 10/2, copper platoon branch.

3 floor practice: see su j 9501-1/3 for light gray non-slip floor tiles in the bathroom; Others: terrazzo floor, Su J950 1-5/3, copper bar grid.

Exterior wall painting: unless otherwise specified, it is light blue elastic paint wall, Su J950 1-22/6.

5 interior wall method: the first floor lobby part: marble wall, Su J 9501-25/5; Toilet: 150×300 white glazed tile wall see Su J950 1-22/5, and the height reaches the bottom of the board; Others: latex paint wall, Su J950 1- 15/5.

6. Kick and platform: In the lobby, marble kick and platform, Su J950 1-6/4, kick 200; The rest, terrazzo skirting, terrace, Su J950 1-5/4, skirting height 150, concealed.

7 Cement corner protector: cement corner protector J950 1-30/5.

Roofing practice: polymer modified asphalt coiled material waterproof roof, Su J950 1-22/7(B), emulsified asphalt expanded perlite for slope, the thinnest part is 70.

9. Flat roof method: for the bathroom part, spray flat roof at the bottom of the board, Su J 9501-3/8; The rest, gypsum board ceiling (1), Su J9501-18, the first floor ceiling is 3000 meters away from the ground, and the first floor ceiling is 3200 meters away from the corresponding floor.

10 paint: ready mixed paint, Jiangsu J950 1-3/9, the contact part between wood members and masonry and the non-exposed part are coated with cypress oil for corrosion protection; Metal base, Su J950 1-23/9

1 1 other: stainless steel stair railings and handrails, handrails and handrails at corners, Su J940 1- 1 30; See su j 9401-130 for the window protective railing; Embedded parts Su J 9505-2/28; Step anti-skid Su J 9505-7/27; Granite terrace su j 9501-7/11; Aproll method: fine stone concrete aproll J 9501-2/12; All the retaining walls and other parts that pick out the wall surface should be drip line, and should be straight, neat and smooth; 120 high concrete water stop is made at the bottom of the bathroom wall from the cast-in-place floor.

Second, the general situation of structural design

1 The reinforcement is grade I steel, grade II steel and low-alloy disc steel.

2. Masonry: Mu 10 and KM 1 block clay hollow bricks are used for the frame filler wall, and Mu 15 fly ash brick and M 10 mixed mortar are used for the elevator shaft wall. Fly ash brick mu15 is used below 0.000; Mortar: M7.5 cement mortar is used below 0.000, and M5 mixed mortar is used above 0.000.

Thickness of concrete protective layer: plate protective layer 15mm, beam and column protective layer 25mm and foundation protective layer 35mm.