The key chapters of building fire prevention include: building classification and fire resistance rating, general plan and layout, fire and smoke prevention zoning and separation, safe evacuation, building decoration, and fire prevention of heat preservation materials.
In this part, you can learn the Code for Fire Prevention in Building Design first, and then learn the teaching materials. Most of the content of the textbook is taken from the code, but the layout is different. Fire code is the most important fire code. The minimum requirement is to read it through several times and be very familiar with it. 13J-8 1 1 revised edition-atlas of fire protection design of buildings is a graphic interpretation of the code for fire protection design of buildings, which is helpful for understanding and remembering. If you don't know the relevant knowledge, you can look through the atlas and articles. Building fire prevention learning is cost-effective, with a score of 30%, but the whole content is a whole, which is easy to summarize and learn systematically. The score of fire-fighting facilities is 50%, but the systems are opposed to each other, which is too professional and difficult to score.
The key chapters of fire protection facilities are: indoor and outdoor fire water supply system, automatic sprinkler system, gas fire extinguishing system, automatic fire alarm system, smoke control system and fire extinguisher configuration in the building.
Needless to say, fire control facilities account for half of the real questions, and practical and comprehensive chapters are almost one-to-one. For a system, the content framework of the two textbooks is the classification, composition, working principle, application scope, main parameters, system composition and setting requirements of the system, and the case is the application of system knowledge. Every system should be understood, and the exam topics are very flexible, and the content is not limited to textbooks. Therefore, the Technical Specification for Fire Water Supply and Hydrant System, the Design Specification for Automatic Fire Alarm System and the Design Specification for Automatic Sprinkler Fire Extinguishing System should be studied (the four specifications for fire protection study: building regulations, fire protection regulations, water regulations and sprinkler regulations must be studied, and other specifications are not recommended, because one's energy and time are limited due to lack of time.
The above is the related content of the textbook for first-class fire engineers shared by Bian Xiao. More information can focus on the construction industry and share more dry goods.