The last section is the most strict, and this section is the second.
Children's plane layout:
1, layout layer requirements:
The first and second floors can only be arranged on the first, second and third floors, and underground and fourth floors are strictly prohibited. This sentence has been tested for many years.
Level 3, level 2, level 4, 1 level.
2. Children are inconvenient to move, so they must set up independent safety exits (2 as standard).
To sum up, electricity, drama and ceremony are at least independent.
3, fire separation: the most common civil is 2 (partition)+1 (floor) +B door, which is the most basic, and exams often pay attention to digging holes on this basis.
Again, let's get familiar with these three points first.
(15A 18) Of the following buildings or floors, the one that can run a kindergarten is ().
A. Rent the third floor of a 6-story apartment building, and the evacuation stairs have not been modified after the fire control acceptance.
(Not independent, not one)
B. Rent the fourth floor of the podium building of a high-rise office building that has passed the fire inspection and can provide independent closed stairwells.
C, rent a semi-basement, which has passed the fire inspection, with an area of 500㎡ and two smoke-proof stairwells.
D, the construction area is 600m2, and the safety, patience and fire-fighting facilities meet the requirements of single-story brick-wood structure houses.
It is said that the safety fire control facilities are qualified and can be single-storey.
Answer: D is too weak to go to four or two independent exits, and it is not difficult to recite three simple words.
(17A64) During the fire inspection of a high-rise multi-functional combined building, it was learned through consulting the data that the fire resistance rating of the building was Grade I, and the floors from 10 to the top floor were ordinary office buildings, and the 9th floor and below were for training, entertainment, business and other functions, and the fire protection zoning met the requirements of the specification. The following building practices, does not meet the current national fire technical standards is ().
The fire pump house is located on the second floor underground, and the height difference between the indoor floor and the outdoor entrance floor is 10m.
(There shall be no less than three pumps, with a height difference of10m)
B There is an early childhood education training class on the sixth floor of the main building, and there are independent safety exits (only the first and second floors, the first, second and third floors).
C The atmospheric gas-fired boiler room is arranged on the roof of the main building, using pipeline natural gas as fuel, and the distance to the safety exit leading to the roof is 10m (6m).
D There is a ballroom on the fifth floor of the podium, and each hall and room has a building area of less than 200m2, sharing a safety exit with other areas.
(Not123200; There is only one independent exit and two independent exits)
Answer: b
Comprehensive: (15X83) When conducting fire inspection on civil buildings, inspectors should pay attention to the fact that special function places are underground or semi-underground, and should not be located in buildings with more than four floors ().
No land, no four, the strictest and the smallest.
A nursery and nursery are qualified.
The inpatient department of hospital B is not on the ground.
C the inpatient department of sanatorium is not away from the ground.
D children's playground and other children's activities are qualified.
E activity place for the elderly (no more than 200 or 30 people in the old photo, the next one is the same as above) Answer: A, D.
The fresh and hot 2 1 year has come.
(2 1A3 1) A fire technical service organization inspected a large commercial accessory. Among the following inspection results, () does not meet the requirements of the Fire Safety Management Rules for Large Commercial Complex (Trial) C Jixiao (2019) No.314.
A, fast food restaurants with an underground construction area of 200m2 adopt electric heating facilities.
B, the children's playground on the fourth floor is equipped with two independent stairs, which can only be arranged on the first, second and third floors.
C. The dining room kitchen on the second floor above ground is arranged by the external wall.
D. The dining room kitchen on the third floor above ground is separated from other parts by firewalls and Class A fire doors.
Answer: B's mistake is too obvious.