How high is the installation height of electrical sockets in primary schools and kindergartens from the ground?
The installation height of electrical sockets in primary schools and kindergartens should be (c) 65438+ 0.8M above the ground.

1. According to the functional requirements of each room in the kindergarten, set corresponding power sockets. At the same time, in order to ensure the safety of children, the installation height of the socket from the ground should not be less than1.80mm.

2. Large indoor activity places in kindergartens generally need to install cabinet air conditioners. It should be noted that the installation height should not be less than1.80m, regardless of whether the cabinet air conditioner socket or cabinet air conditioner switch box is installed. ..

3. Equipment such as food processing, kitchen smoke exhaust, drinking water and domestic hot water in kindergarten should be planned reasonably in the design stage to avoid the situation that the power supply is not in place and the power supply load is insufficient.

4, kindergarten play pool (water depth is not more than 0.3m), should be local equipotential connection.

Methods Refer to 02D50 1-2 equipotential bonding installation-an example of local equipotential bonding in fountain; Safe voltage power supply and leakage protection devices should be adopted to ensure the personal safety of children.

Extended data

Nursery and kindergarten rooms should be equipped with sockets, and the location and quantity should be determined according to the needs. There should be no less than four sets of sockets in the activity room, and no less than two sets of sockets in the bedroom, library and art room.

The socket should be safe, and the installation height should be no less than1.8m. The socket circuit and lighting circuit should be set separately, and the socket circuit should be provided with residual current protection.

It is not suitable to install electrical devices such as distribution box and control box in children's activity places; If it is unavoidable, safety measures should be taken, and the height from the bottom of the device to the ground should not be less than1.8m.