Overview of architectural design:
1, moistureproof of wall foundation: Su J9501-1,which is not provided where there is a geosphere beam.
2. Ground practice: the stacks are partially overhead: terrazzo floor, Su J950 1-5/3, with copper bars. Hall part: granite floor, Su J 9501-18/2; Fire control room: single-story hardwood floor, Su J 9501-20/2; See Su J9501-14/2 for the light gray non-slip floor tile in the bathroom; The rest: terrazzo floor, Su J950 1- 10/2, copper platoon branch.
3. Ground practice: See Su J9501-11/3 for the light gray non-slip tile floor in the bathroom; Others: terrazzo floor, Su J950 1-5/3, copper bar grid.
4. Exterior wall painting: unless otherwise specified, it is light blue elastic paint wall, Su J950 1-22/6.
5. Interior wall method: the first floor lobby part: marble wall, Su J 9501-25/5; Toilet: 150×300 white glazed tile wall see Su J950 1-22/5, and the height reaches the bottom of the board; Others: latex paint wall, Su J950 1- 15/5.
6. Kick-off and platform: in the lobby, the marble kick-off and platform, Su J950 1-6/4, the kick-off height is 200; The rest, terrazzo skirting, terrace, Su J950 1-5/4, skirting height 150, concealed.
7. Practice of cement corner protection: cement corner protection line Su J950 1-30/5.
8. Roofing practice: polymer modified asphalt coiled material waterproof roof, Su J950 1-22/7(B), emulsified asphalt expanded perlite for slope, with the thinnest part of 70.
9. Flat roof method: for the bathroom part, spray flat roof at the bottom of the board, Su J 9501-3/8; The rest, gypsum board ceiling (1), Su J9501-18, the first floor ceiling is 3000 meters away from the ground, and the first floor ceiling is 3200 meters away from the corresponding floor.
10. Paint: ready mixed paint, Su J950 1-3/9, the contact part between wood members and masonry and the unexposed part are coated with cypress oil for anticorrosion; Metal base, Su J950 1-23/9
1 1, others: stainless steel stair railings and handrails, handrails and handrails at corners, page J940 1- 1 30; See su j 9401-130 for the window protective railing; Embedded parts Su J 9505-2/28; Step anti-skid Su J 9505-7/27; Granite terrace su j 9501-7/11; Aproll method: fine stone concrete aproll J 9501-2/12; All the retaining walls and other parts that pick out the wall surface should be drip line, and should be straight, neat and smooth; 120 high concrete water stop is made at the bottom of the bathroom wall from the cast-in-place floor.
For more information about project/service/procurement bidding, and to improve the winning rate, please click on the bottom of official website Customer Service for free consultation:/#/? source=bdzd